Abstract Over the last several decades, medical imaging technologies have proven so anatomically insightful that they have all but taken over management in many clinical situations. MRI, CT, and PET scanning technologies employ stringently controlled rotational data-harvest protocols. By contrast, standardization of visible-light imaging of human anatomy has lagged dramatically. This article is the first to present a rigidly standardized rotational protocol to photographically record human anatomy and permit subsequent analysis with less than 2% image variance.

 


Keywords 3-Dimensional photography, anatomy, body contouring, body shape, circumferential imaging, clinical photography, digital imaging, growth and development, plastic surgery, rotational imaging, standardized photography

 

Introduction

Images of scientific and medical subjects were captured within a year of the invention of photography. Later, photographs of Civil War casualties became iconic, bringing medical images to public attention and sparking their use for medical documentation and education. Medical photography subsequently grew as a defined specialty, and professional standards were developed. In the 1930s, hospitals began creating departments for medical photography to allow clinicians in many medical and dental specialties to document patient anatomy or disease processes. By 1966, photography was being used as a critical day-to-day component of clinical care in several specialties, including Plastic Surgery (Spear and Hagan 2008). Since then, many authors have stressed the importance of incorporating strict standardization of clinical imagery (Gherardini et al. 1997, Williams and Nieuwenhuis 1992, Peres et al. 1996) but we believe that the incomplete standardization proposed in previously published protocols (with resultant inability to extract meaningful data from the imagery) has prevented widespread adoption of the published methods.

 

Starting in the late 1980's, an explosion of highly standardized computer-generated imaging technologies (CT, MRI, and PET-Scans) not only allowed visualization of interior body spaces but made clinical photographs of the body surface seem simple and "old-fashioned." By the time digital cameras eclipsed the resolution of film in the late 1990s, few medical practitioners continued to use clinical photographs as sources of meaningful data. Rather, the ease of automated 'point and shoot' technology enticed Plastic Surgeons and others to produce unlimited and inexpensive "medical snapshots." Although most clinicians were satisfied with the resulting images to document their activities for the medical record and publication, the potential to obtain scientific data from these non-standardized visual anecdotes was lost (Teplica 2009).

 

In recent years, readily available and sophisticated computer software provided a precise and consistent tool for the possibility of detailed analysis of the anatomic information contained in medical images, but this could only occur if the images were adequately standardized. Unfortunately, to date, surgical imagery rarely is sufficiently standardized to permit this type of anatomic analysis. Of equal importance, circumferential images are only infrequently obtained despite a growing awareness that the body must be perceived 3-dimensionally and in the context of all adjacent anatomic regions (Teplica and Bundy 1996, Rohrich et al. 2006, Dabb et al. 2004).

 

The literature is virtually silent regarding reproducibility as it pertains to the various methods for standardizing clinical photography. The purpose of this paper is to outline an easily mastered, reproducible, and highly standardized, rotational photographic method to image the torso for meaningful anatomic comparison and analysis. New insights into anatomic mirroring of faces and body form in monozygotic twins (Teplica and Peekna 2005, Teplica 2010) and a published description of disease-influenced anatomic changes (Teplica 2013) make it more urgent that techniques be adopted to better document human surface anatomy in a quantifiable manner. Ideally the method would capture anatomic form and the bodily variations that occur over time, with gender, and as a result of hormonal changes, trauma, pharmaceutical exposure, and disease. Standardized digital strategies that are currently being used in radiology (MRI, CT, and PET scanning) yield insights far beyond what could ever be imagined by the historical pioneers of standardized human photography, including Eadweard Muybridge, W. H. Sheldon, and Alphonse Bertillon. Unfortunately, standardization for clinical and investigational photography (visible-light imaging) has lagged all the other modalities. With a growing emphasis on research that quantifies the effects of medical, surgical, and pharmaceutical interventions, highly standardized digital protocols must be refined for photographic imaging so that real data can be obtained to quantify treatment outcomes, track progression of anatomic change (from all causes), and facilitate anatomic discovery.

 

 

 Photographic Set-Up

Strict consistency is as critical in clinical photographs as it is in all other forms of medical and scientific imaging. It is interesting to note that all other sophisticated forms of body imaging occur in dedicated spaces with equipment that is built to analyze anatomy from strictly standardized distances, using strictly standardized protocols. Ideally, a body-imaging studio would be installed with dedicated equipment that is structurally locked into position to ensure identical capture of anatomy. Few if any medical centers or offices have recognized the need for a dedicated and standardized space to photographically image the surface of the body. Nor do many (if any) facilities demand strict standardization of camera, lens, shutter speed, aperture, lighting, distances, rotational positions, or any other variables that would make the comparison and analyses anatomic data possible – either between different individuals or to document changes in a single individual who changes over time. In other words, to produce valid scientific images, photographers and medical personnel should strive to capture clinical or investigational photographs in which the ONLY variable is the anatomy itself.

 

Details for the elements that can be successfully controlled/standardized are provided in Table 1. This information can be used to guide creation of a dedicated space or (much less accurately and much less desirably) to set up equipment in a multi-use space for each imaging session.

 

 

Table 1. Elements Requiring Standardization in Clinical Photography.

 

 

A backdrop large enough to eliminate all extraneous objects from the final image is needed. A minimum background size of 1.33 meters wide and 2.0 meters high consistently allows full-torso imaging of subjects without capturing room details. In addition, these dimensions permit circumferential imaging with clearance of limbs during each full rotation. The color of the background should allow for visual anatomic separation, not reflect colored light that distorts natural skin tones, and not interfere with image analysis. A flat black backdrop not only meets all the above goals, but also embraces the well-established standards of the biomedical imaging community (Williams and Nieuwenhuis 1992), while permitting digital image analysis (Gherardini et al. 1997). Black is the most easily standardized and it shows no distracting shadows. These critical criteria are not met by any other color choice.

 

 


Figure 1.
Basic construction of the turntable, showing white markers at 15° increments, with larger dots at 45°. The subject's toes should create an imaginary line parallel to the front edge of the turntable. Ideally, this will result in the anterior surface of the body being coplanar with the sensor plate of the camera. If the subject has pelvic or spinal malalignment, the feet can be adjusted to improve anterior positioning. Alternatively, the subject can be asked to rotate one hip forward to align planes, though this option is hard for the subject to maintain throughout the full imaging sequence.

 

A rotating turntable (Figure 1) with ball-bearing wheels that move freely around a central axis -- regardless of subject weight – is an essential element of the set-up. A pointer on the base of the rotating platform allows alignment with white reference marks placed at 45° increments on the platform base. Circumferential photographs are routinely captured at these specified increments, which correspond perfectly to positions commonly referred to (but never conceptually acknowledged numerically) as: "frontal" (0°), "right oblique" (45°), "right lateral" (90)°, "right posterior oblique" (135°), "back view" (180°), "left posterior oblique" (225°), "left lateral" (270°), and "left oblique" (315°). We advocate use of the degrees designators to stress the scientific nature of imaging and to encourage accuracy of the rotational increments. If more detail is needed than what can be obtained with 45-degree rotations, for example if 3D modeling is desired, then smaller incremental rotations can be easily obtained.

 

The turntable should be centered in front of the backdrop. The distances between 1.) the rotational axis and the sensor plane in the camera, 2.) the rotational axis and the backdrop, and 3.) the subject and light sources must remain constant in order to ensure lighting consistency. A non-zooming (fixed focal length) macro lens is chosen with goals to produce the least anatomic distortion and most consistent focus. For any given digital SLR camera, a lens should be chosen that captures anatomy in a way that approximates the optics of the human eye, thereby minimizing errors of perception in the clinical setting. We have chosen the Nikkor 65mm Macro Lens and have not been able to discern any difference between our images and perceived reality. When the rotational axis of the platform is placed a minimum of 60 cm in front of the backdrop, subjects can rotate freely through all clinically relevant body and limb positions without having arms hit the background during rotation. A fixed distance of 4 meters from the rotational axis to the camera's sensor plate ensures that anatomy is digitally captured at a fixed reproduction ratio. The tripod-mounted camera then is leveled and adjusted in a left-right direction to ensure that the barrel of the lens and the platform's rotational axis create a line that is perpendicular to both the anatomic plane and the backdrop. Focus is obtained by having the subject press a metric ruler firmly against the skin of the upper abdomen, allowing the autofocus mechanism in the camera to find and fix on this standardized location. Autofocus is then turned off, so the lens is fixed, preventing errors of reproduction ratio in the final imagery.

 

In order for the lighting to appear natural, the shadows should fall downward (Vetter 1992). Overhead studio lighting should be fixed at 45° lateral to the rotational axis and 45° above the imaginary plane that passes through the optical center of the lens and the subject's umbilicus. Point sources of light in the strobes (without diffusion or reflective umbrellas) create shadows that best mimic natural sunlight. Supplemental lighting is necessary to fill the shadows inevitably created by the overhead lighting, so that anatomic detail is captured. Unfortunately, top-mounted flash creates harsh shadows that further block anatomic detail. Side-mounted (unilateral) flash creates unwanted asymmetry and data-blocking deep shadows on the side of the body opposite the flash. We have found that ring flash that surrounds the lens circumferentially is the best choice, providing subtle symmetrical fill-light for shadows and the slight 'flattening' of the appearance of the anatomy does not overpower volume perception created by the overhead lights if the power ratio of the overhead to ring-light is 2:1 or less. In our experience, the combination of overhead point sources of light combined with the Nikon SB-29s ring flash at full power consistently gives superb volume rendition and adequate anatomic shadow details. Before the imaging session begins, the photographer should confirm that the camera and flash batteries are fully charged. Stopping an imaging session to change batteries can throw the camera out of register and destroy critical focus, while low battery power can lead to inconsistent exposures if the photographer fails to realize that a "ready-light" has not illuminated. In our experience, devastating errors of exposure can be eliminated if fresh or newly charged batteries are used each time. This also ensures that recharging time is minimized to allow the rotations to happen as quickly and safely as possible.

 

 

 Subject/Patient Imaging

Upon arrival, consent for imaging is obtained, then the subject is provided with a loose-fitting robe and is asked to remove all clothing and jewelry in complete privacy. Once the subject has changed, the photographic procedure is explained, and questions any questions are answered. It is important to explain that, because each position has its own set of advantages and disadvantages (Table 2), the photographer must capture three full image sequences to ensure visibility of all undistorted surface anatomy—one with arms down in the neutral anterior position, one with arms down in the neutral posterior configuration, and one rotation with arms elevated. During the dialog and studio preparation, elastic and other clothing marks should dissipate. Ask the individual being imaged to step onto the rotating platform and position both feet so an imaginary line connecting the great toes is parallel to the front edge of the base. (Figure 1) Ensure the subject's center of gravity is directly over the central axis of the turntable, usually by balancing the weight between both feet. Basic studio setup is shown in Figure 2




Figure 2.
The standardized setup can be integrated into an existing office or clinical space, here with only the tripod needing to be disassembled to permit normal traffic flow within the room. The relative positions of the backdrop, turn-table, imaging subject, the assistants, overhead lights, tripod, camera, lens-mounted ring flash, and photographer can all be seen. Importantly, patients or imaging subjects should always be given the option of a chaperone to enhance comfort and safety. In the depicted research project, a female subject underwent standardized torso photography once a week throughout her entire pregnancy to document volumetric expansion and anatomic changes in focal fat pad anatomy. A female member of the research group served to rotate the platform and the subject selected a male member of the team as her dedicated chaperone. With concerns about getting light-headed during imaging, this gentleman's size and strength gave the woman reassurance, as he was assigned specifically to watch for signs of a vaso-vagal response (pallor, sweating, glazed eyes, or decreased alertness) that could indicate that she was about to faint. Although he never needed to intervene, he was poised to respond quickly to protect the woman and her developing baby. As shown, a fan can also decrease the likelihood of a vasovagal fainting response. This documentary photograph was taken by Joe Ciarrocchi in 2014.

 

 

Table 2. Advantages and Disadvantages of the Three Imaging Positions.




Figure 3.
Digital subtraction shows the significant positional change that occurs in the chest and shoulders between inspiration and expiration. Complete disappearance of the abdomen and lower extremities indicates that there is no significant anatomic variance in the lower half of the body with respiration. However, the dramatic change in nipple position and shoulder height reinforces the need to capture all clinical photographs at average expiration –not forced or maximal– if one is imaging the upper half of the body.

 

 

With robe on, ask the subject to assume a comfortable upright posture, but not rigid or forced, and with the shoulders relaxed. Using a tape measure to ensure accuracy, determine the distance of the umbilicus from the floor, and adjust the tripod up or down so the optical center of the lens is at the exact level of the center of the umbilicus. Finally, check the positioning in the view finder. This standardization format should capture all relevant anatomy for the great majority of subjects – extending from the chin to mid-calves in all but the very tallest of subjects. Only in the rare extremely tall individual will it be necessary to obtain several supplemental views (AFTER the standardized sequences are complete) to capture the distal-most portions of the lower extremities. With one end of a meter-long ruler resting on the rotating platform, focus is obtained by having the subject press the other end of the ruler against the anterior inferior rib cage. The center-weighted auto focus or the photographer's eye (in manual focus mode) can use the 1 mm divisions on the ruler to obtain focus. If autofocus was used, focus is then locked (or turned to Manual Mode) once focus is obtained and is not adjusted again throughout the imaging session.

 

Allow approximately 45 minutes for each photographic session. Immediately prior to taking the first image, the robe is removed. The use of modesty garments is not recommended as they interfere with anatomic visualization in full-torso imaging and circumferential tracking. As an example, in the field of plastic surgery, circumferential body contouring is quickly becoming the standard of care, usually with attention to the buttocks, hips, inner thighs, and the pubic mound. Covering anatomic sites that will undergo surgical treatment or be tracked for changes over time cannot have coverage (Gherardini et al. 1997, Teplica and Bundy 1996). Imaging subjects should be told that their images do not include faces.

 

All images in every sequence should only be taken after the subject gently exhales to ensure consistency and because the process of inhalation/exhalation alters the nipple-areolar position significantly. (Figure 3) In addition, the act of exhalation allows surgeons to consistently document native anatomy without muscular contraction, as it tends to cause relaxation of other muscle groups. Moreover, photographing at exhalation memorializes the least flattering views of a surgical patient's anatomy, both before and after surgery. This practice contrasts with the unfortunately common and anatomically deceptive technique when pre-operative views are obtained at expiration and post-operative views are captured at inspiration, thereby falsely enhancing perceived surgical changes. Once set-up is complete and test images have been obtained to ensure appropriate positioning, lighting, focus, and exposures, the subject is asked to remove the robe, and final adjustments are made to confirm that hand and body positions are correct. Take the first photograph at the "neutral anterior" position (other hand positions are described below). Proof the camera image to ensure that posture is truly vertical and that the body does not torque to the left or right. Pelvic and shoulder girdles twisted unwittingly and imperceptibly, but the entire anterior planar surface of the body must be perpendicular to the long axis of the lens to enhance the standardization process. Hips or chest may have to be rotated to have the anterior surface planar and without twist. Coach the subject through positional adjustments and ask that they hold the position throughout the rotational sequence.

 

Ask the subject to close both eyes before rotating the platform counterclockwise to the 45° (right anterior oblique) view. Then, ask the subject to open the eyes and to gently inhale and exhale before the second image is taken. Closing the eyes during rotation helps maintain consistent anatomic position; inadvertent twisting often happens if eyes are open, as subjects tend to fix their gaze while being rotated. The head, neck, and chest tend to turn less than the lower half of the body, creating an anatomic twist that destroys standardization and renders post-surgical comparisons unreliable. The photographic session should proceed efficiently until all 45° incremental images are captured. Repeat the remainder of the complete imaging process as outlined stepwise in Table 3.


For the first rotation of torso imaging, the subject's hands overlap in the midline resting on the buttocks with thumbs in their palms and the left hand loosely cupped inside the right. This is the "neutral anterior" position. (Figure 4) For the second rotation, the subject cups the hands loosely over the groin, with thumbs in palms and the left hand inside of right, to establish the "neutral posterior" position. (Figure 5) The third standard position is "arms-up" (Figure 6) with a salute-like configuration with palms facing the floor, middle fingertips pressing against the skull just above the ears, and with the elbows in the plane of the chest. Three complete rotations – one for each hand position – document the entire skin surface of the torso circumferentially, permitting immediate and future anatomic evaluation, digital addition and subtraction of images for clinical or investigational purposes, or to document anatomic changes (when different imaging sequences are compared over time).

 

 


Figure 4.
Arm and hand positions for the "neutral antereior position" for unobstructed capture of the front half of the body. The subject stands erect with relaxed shoulders, a straight back, and with weight evenly distributed between the feet. Hands hang freely in the midline atop the buttocks, with the left hand loosely cupped inside the right.

 

 

Figure 5. Arm and hand positions for the "neutral posterior position" for unobstructed capture of the back half of the body. The individual being imaged stands erect with relaxed shoulders, a straight back, and with weight balanced between the two feet. Hands are placed atop each other over the groin, with the left hand cupped inside the right, although not holding or cupping the genitalia.

 

 

Figure 6. Arms up position for unobstructed capture of the circumferential torso, albeit with stretch-distortion caused by arm elevation. (Left) Frontal view at 0°. Similar to saluting, the subject places his middle finger against his skull just above the helix of the ear. Palms are flat, facing the floor with thumbs against the index fingers and with elbows within the plane of the chest. (Right) Side view at 270°. This position places the long axis of the upper arm at 90° to the sagittal plane of the body and parallel to the floor.

 

 

To optimize comfort and propriety, never touch the nude subject, even if a third party is present, and do not look directly at the subject—restrict your viewing through the camera lens or onto the image screen. Before terminating the session, ask the subject to maintain the standardized position without moving while you cycle through all digital images to ensure proper image capture. Occasionally, an image must be retaken because of flash synch errors, air born dust flares, or if the subject unwittingly shifted position or if they were inhaling instead of exhaling. Errors can quickly be recaptured by rotating the subject to the correct station. Once the imaging results are satisfactory, hand the robe to the subject, then stabilize the platform, and extend a hand to help them step off the turntable, then ask the subject to redress as you leave the room. Table 3 provides a detailed stepwise description of the process.

 

 Imaging Results

Figure 7 shows a sequence of the most clinically most useful images (selected from the 3 rotations with 9 images each) that allow circumferential visualization of full body form. We recommend capturing a full image sequence with each of the three hand positions to thoroughly document body surface and shape, facilitating future anatomic analysis for the vast majority of scientific and clinical situations. Importantly, these same images also lend themselves to detailed quantitative comparison of anatomic change with time and for pre- and post-operative states in plastic surgical patients.

 

 


Figure 7.
A composite image sequence of selected standardized views of the torso at 45° increments that allow complete visualization of the body form and the skin surface. Although all three hand positions were captured at each 45° station for the full rotation, this composite shows only those views that are deemed most clinically useful, chosen from each clinical station. Selection of appropriate hand positions will depend upon the anatomy being evaluated for any given subject. Alternatively, a composite could be created using all 12 views from each of the 3 rotational sequences.

 

The technique is incredibly consistent and reproducible as seen in the composite illustration (Figure 9). A direct comparison of unaltered photographs obtaining using the imaging technique by three individuals with vastly different levels of photographic experience and training is presented. As shown, remarkably similar outcomes (less than 1.7% error in all measured axes) can be achieved, whether the photographs were captured by a completely untrained office staff member, an individual with minimal photographic experience, or by a professional with both photographic and surgical training. (Figure 10)

 


Figure 8.
Comparison of images captured by three different photographers at the 45° rotational increments as outlined in Table 2. The image-makers had vastly different levels of photographic skill and familiarity with the protocol. The degree of similarity is far beyond what is normally achieved in the best of hands without using a strict standardization protocol. The most obvious error of imaging was the failure of the medical student to place the hands in the correct position for visualization of the posterior anatomy. Most notably, the images captured by the photographically untrained office assistant (without knowledge of the protocol or goals) is nearly identical to the sequence obtained by the senior author (DT) with a 25-year experience refining the technique. Of interest, the medical model exhibits a significant degree of left hemicorporal microsomia with a shorter left torso, a smaller left buttock, a left leg shorter than the right, and with a resultant downward tilt to the pelvis and scoliosis of the spine, none of which were appreciated until the image sequences were assembled.

 


Table 3. Studio Protocol for Producing Full Torso, Highly Standardized Images

 

 

 

Figure 9. Analysis of variance in image capture by the three photographers in Figure 8, who had different levels of photographic experience and familiarity with the imaging protocol. The percent variances shown in each image correspond to the alignment of the following points: top left: left nipple; top right: right nipple; bottom left: umbilicus; and bottom right: the alignment of the points where the inter-nipple line and a vertical line from the umbilicus meet. All image variances are less than 1.7%, well within limits for valid scientific analysis, while image variance in CT and MRI can be as high as 10%.

 

 

Figure 9 shows image variance (error) analyses when four separate anatomic points of reference were held constant (left and right nipples, mid-point of the chest, and the umbilicus). Image overlay allowed quantification of rotational error and positional differences. The average vertical error among all four anatomic points of reference was 0.69%. Average horizontal error amounted to 1.2%. Overall, the average positional error (horizontal and vertical) was 1.0%. Average angular (rotational) error was calculated to be 1.2 degrees (0.65%). If desired, variance in anatomic size can also be calculated using this method, although it is not shown in this sequence.

 

 

Figure 10. (Left) Preoperative view. (Right) Postoperative view. (Middle) Digital subtraction analysis of highly standardized "Before and After" photographs, illustrating how actual surgical change can be quantified with high confidence.

 

 

 Comments and Considerations

This paper presents the first description of a stepwise, highly standardized protocol for photographically capturing human anatomy over a full 360° rotation in a reproducible way. The protocol functions well in the world of medicine and surgery for a variety of patient-care applications where quantification of changes would be useful: (1) evaluating a single patient over time to document surgical changes from the pre- to the post-operative stages (Figure 10); (2) documenting disease progression; (3) assessing changes in developmental anomalies over time; (4) making valid, quantitative circumferential comparisons between surgical patients; (5) tracking anatomic aging; (6) documenting and analyzing changes in body form caused by hormonal change; and many more clinical situations.

 

Absent strict standardization, anatomic imagery is only anecdotal, but highly standardized rotational photography provides an enormous cache of reproducible data for the complex analysis of anatomy and anatomic change. Following the stepwise set-up presented and using the protocols outlined, a wide range of image-makers can quickly start producing superb imagery with little anatomic variance. If all variables are held constant -- except for the actual anatomic changes – the photographer can utilize existing software (such as Adobe Photoshop) for the detailed analysis of 3-dimensional form and the quantification of change with small amounts of error that are calculable and acceptable. Surgical outcomes, the effects of pharmaceuticals, disease progression, human growth and development, and the process of aging would all be informed by real anatomic data. To optimize results and reproducibility, we recommend that the protocol, as outlined in Table 3, be followed at every photographic session.

 

On rare occasions, an imaging subject may experience a vaso-vagal episode during the photographic process, especially if knees are "locked" in a parade-like stance. We recommend that the subject be informed in advance to immediately let the staff know if they are feeling light-headed or nauseated and that the imaging session be terminated immediately and that the session only be re-launched once the subject is hydrated and stable.

 

Direct transfer of the images to a tethered computer monitor allows the subject to see that face and identity are not being captured and permits the photographer to immediately inspect and correct any visible lapses in standardization. Also, we highly recommend that a GretagMacbeth color card (or similar) be incorporated into the first image taken of any subject to allow for tracking of color consistency or for color correction, if necessary. In an effort to better standardize the issue of inspiration/expiration and timing the shutter to happen only after expiration, we are considering having the subjects audibly exhale at each station, so the image can be captured only after that sound has been heard. Those exhalations must only be small and modest to prevent the subject from blowing off too much carbon dioxide and becoming dizzy from hypocapnia. Finally, with concern for the safety of the imaging subjects, we offer and provide an assistant/chaperone to stand off to the side (out of the field of capture) as indicated. It is rare for young subjects to need assistance, but elderly, pregnant, or disabled individuals routinely reassured and helped by an assistant who provides support.

 

 

 Conclusions

It is possible to achieve highly standardized photographs of human torso anatomy with very little variance between imaging sessions using a standardized protocol and rotational imaging strategies as presented. The method described affords many new and exciting possibilities for anatomic discovery, data analysis, and the potential to quantify anatomic change over time, whether from aging, hormonal influence, disease progression, or surgical intervention. The method may also provide a more efficient and cost-effective way to promote visible light imaging in healthcare delivery systems, like that in the United States, where insurers are reluctant to reimburse for the service.

 

 

 Acknowledgements

The senior author (D.T.) received financial and in-kind support during development of the standardized rotational photographic protocols from an NIH Surgical Scientist Training Grant, the Center for Study of Multiple Birth in Chicago, and the former Professional Photography Division of the Eastman Kodak Company, Rochester, NY. The 803 Foundation of Chicago provided critical financial support for completion of this manuscript. The Kinsey Institute of Bloomington, Indiana has provided inspiration and reinforcements for the need image and understand the human body. The American Institute of Bisexuality of Los Angeles, CA provided significant and critical support for the refinement of the imaging protocols and the implementation of strategies to better analyze human bodily phenotypes, especially as they relate to the anatomy of sex and the perception of gender and sexuality. Dr. Louis Keith provided significant editorial insight and direction. Kalev Peekna helped our team understand and implement computer-based technologies for standardized digital image capture and analysis, as well as for the presentation of visual data. Haley Tucker and Adam Hawks collaborated on the production of the illustrations. Drs. Tom Krizek, Larry Gottlieb, and Gary Burget gave inspiration and encouragement from a surgical perspective to the senior author (D.T.) for development of the standardized technique. Eileen Jeffers provided important project support and editorial insights and Alex VanOeveren gave generously of his time for data acquisition and illustration production. Lastly, the senior author is incredibly grateful to Professor Michael Peres, Associate Chair, School of Photographic Arts and Sciences, College of Art and Design at the Rochester Institute of Technology for providing critical early guidance, insights, and encouragement.

 

The information in this article was first presented as the Maria Ikenberg Lindberg Keynote Address at the 79th BioComm in Park City, Utah.

 

 

 References

Dabb, R., Hall, W., Baroody, M., and Saba, A. 2004. Circumferential suction lipectomy of the trunk with anterior rectus fascia plication through a periumbilical incision: an alternative to conventional abdominoplasty. Plast Reconstr Surg. 113(2): 727-732; discussion 733-724.

 

Gherardini, G., Matarasso, A., Serure, A., Toledo, L., and DiBernardo, B. 1997. Standardization in photography for body contour surgery and suction-assisted lipectomy. Plast Reconstr Surg. 100(1): 227-237.

 

Peres, M., Teplica, D., and Burns, S. 1996. Nudity in clinical photography: a literature review and the quest for standardization. J Biol Photogr. 64(1): 3-13.

 

Rohrich, R., Gosman, A., Conrad, M., and Coleman, J. 2006. Simplifying circumferential body contouring: the central body lift evolution. Plast Reconstr Surg. Aug 2006; 118(2): 525-535; discussion 536-528.

 

Spear, M., and Hagan, K. 2008. Photography and plastic surgery: part 1. Plast Surg Nurs. 28(2): 66-70.

 

Teplica, D., and Bundy, M. 1996. Guidelines for inclusion of psychologically sensitive anatomic regions. J Biol Photogr. 64(1): 27-28.

 

Teplica, D., and Peekna, K. 2005. The mirror phenomenon in monozygotic twins. In Multiple Pregnancy: Epidemiology, Gestation & Pernatal Outcome. London: The Pathenon Publishing Group.

 

Teplica, D. 2009. Viewpoint: Recapturing science in clinical photography. J Biocommun. 35(2).

 

Teplica, D. 2010. The genetic basis of body shape: Lessons from mirror twins and high-definition digital photography. Virtual Mentor. 12(5): 412-417.

 

Teplica, D. 2013. Autologous fat grafting and injectable dermal fillers for human immunodeficiency virus-associated facial lipodystrophy: a comparison of safety, efficacy, and long-term treatment outcomes. Plast Reconstr Surg. 131(3): 507-509 discussion.

 

Vetter, J. 1992. Biomedical photography. Boston: Butterworth-Heinemann.

 

Williams, R., and Nieuwenhuis, G. 1992. Clinical and operating room photography. In Biomedical photography. Boston: Butterworth-Heinemann.

 

 

Authors

David Teplica, MD, MFA has a career bridging photography, anatomic research, and surgery. He is a Board-Certified plastic surgeon serving on the Clinical Faculty of the University of Chicago. During surgical training, he received the Trustee's Scholarship from the School of the Art Institute of Chicago and earned a Master of Fine Arts in Photography. Using standardized photography, Teplica has published valuable anatomic findings gleaned from identical twin subjects, giving a better understanding of human growth and development and the embryological origins of basic adult anatomy. He is currently tracking anatomic changes due to aging, hormonal shifts, and the HIV virus, while refining his imaging systems. As Senior Research Fellow at The Kinsey Institute with funding from the American Institute of Bisexuality, Teplica is using standardized imagery to define the differential anatomy of gender and to correlate findings to sex-chromosome makeup, gender identity, and sexuality. He is a long-standing member of the BioCommunications Association.

doctor@davidteplica.com

 

Daniel Schuleman, JD is a practicing attorney in Chicago, IL who focuses on commercial insurance coverage. As an active and accomplished photographer with a long-standing interest in the medium, he spent a summer before law school as a Photographic Research Intern with Dr. Teplica and The 803 Foundation and worked to develop strategies for quantification of error in clinical photographs.

 

Vanston Masri, DO is Board-Certified in both Anesthesiology and Pain Medicine by the American Board of Anesthesiology. During medical school, Dr. Masri served as Research Intern with Dr. Teplica and assisted with development of imaging protocols to capture anatomy. He helped with data acquisition, illustration creation, and manuscript preparation and editing. He completed his residency in Anesthesiology at MetroHealth Medical Center of Case Western Reserve University and his Fellowship in Pain Medicine at The Johns Hopkins University School of Medicine. He currently practices in Denver, Colorado.


 

Disclosure

None of the authors has any financial disclosures or any other conflicts of interest regarding materials, products, or methods described in this paper.


 

Photographic Consent

Paid medical models were used to develop and test the mechanical and digital imaging systems described in this paper and provided consent for the reproduction of their information and imagery. The one surgical patient depicted in Figure 10 gave written consent for the use of his de-identified information for research, education, and publication purposes.

 

 

Licensing

The authors have chosen to license this content under a Creative Commons Attribution, NonCommercial, NoDerivatives 4.0 International License.